A. O. Smith Voltex MAX / Signature 900 Premium (HPTA, HPA10) error code 081

Condensate management

What it means

Condensate management. NOTICE: The Control Assembly will go into Limp Mode 3 until the failure is corrected.

How it shows: with an alert icon flashing (also flashing red LED and beeper)

Source: Hybrid Electric Heat Pump Water Heater Installation Instructions and Use & Care Guide (Premium/Smart Valve), 100379654_2000812401, page 27

What A. O. Smith says to do

1. Ensure unit is installed level. 2. Check for blocked condensate drain line, clear drain line as necessary. 3. If an accessory condensate pump was installed: Turn OFF power to the water heater at the breaker and check control wire connections to condensate pump. Reconnect power. 4. Check to see if the accessory condensate pump is plugged in and has power. 5. Ensure the pump is operating properly, check pump outlet tube for blockage. 6. Repair or replace accessory condensate pump as necessary. 7. If problem persists, call our Technical Assistance Hotline which is listed on the water heater's warranty sheet.

The manual adds: "These instructions are brief and intended as guidance for a qualified person. If you lack the necessary skills to perform these procedures call the Technical Assistance Hotline which is listed on the water heater's warranty sheet for assistance." (Hybrid Electric Heat Pump Water Heater Installation Instructions and Use & Care Guide (Premium/Smart Valve), 100379654_2000812401, page 27)

Last checked 2026-10-03.