A. O. Smith Voltex AL Smart / Signature 900 Standard (HPTS, HPS10) error code 003

Upper thermistor sensor failure

What it means

Upper thermistor sensor failure. Upper thermistor sensor is mounted to tank and located above upper element. NOTICE: The Control Assembly will go into Limp Mode 1 until the failure is corrected.

How it shows: with an alert icon flashing (also flashing red LED)

Source: Hybrid Electric Heat Pump Water Heater Installation Instructions and Use & Care Guide, 100379659_2000812395, page 25

What A. O. Smith says to do

These steps involve electrical testing or parts replacement. A. O. Smith's manuals tell owners to leave that work to a qualified service technician.

1. Turn OFF electrical power at the breaker. 2. Check electrical connections at Control Assembly board. 3. If there are no issues with the wiring, replace the thermistor. 4. Turn ON electrical power at breaker.

The manual adds: "These instructions are brief and intended as guidance for a qualified person. If you lack the necessary skills to perform these procedures call the Technical Assistance Hotline which is listed on the water heater's warranty sheet for assistance." (Hybrid Electric Heat Pump Water Heater Installation Instructions and Use & Care Guide, 100379659_2000812395, page 27)