Hybrid Heater Codes

Rheem · ProTerra / Performance Platinum hybrid (Gen V, 240V)

Rheem ProTerra / Performance Platinum hybrid (Gen V, 240V) error code A126

Upper Element Error or Relay Stuck Closed

What it means

Heating element or control board failure. Heater disabled.

Source: Electric Residential Hybrid Water Heater Use & Care Manual With Installation Instructions for the Installer, AP23657 Rev 04, page 34

Also listed in: Electric Residential Hybrid Water Heater Use & Care Manual (earlier revision), AP23657 Rev 01, page 33

Also listed in: Electric Residential Hybrid Water Heater Use & Care Manual (earlier edition), AP21681, page 28

What Rheem says to do

These steps involve electrical testing or parts replacement. Rheem's manuals tell owners to leave that work to a qualified service technician.

Disconnect power to unit 2. Check resistance on element per included Ohm Reading Chart 3. If acceptable ohm reading is present, replace board 4. If ohm reading is not as it should be per included chart, replace

Last checked 2026-10-03.

Safety first

From the manufacturer's manual for this series.

The same code on other models

Codes mean different things on different heaters. Match the series to the model number on your rating label.

Other ProTerra / Performance Platinum hybrid (Gen V, 240V) codes