Hybrid Heater Codes

Rheem · ProTerra / Performance Platinum hybrid (Gen V, 240V)

Rheem ProTerra / Performance Platinum hybrid (Gen V, 240V) error code A902

Controller Fault: Call Tech Service

What it means

Controller malfunction. Heater disabled.

Source: Electric Residential Hybrid Water Heater Use & Care Manual With Installation Instructions for the Installer, AP23657 Rev 04, page 35

Also listed in: Electric Residential Hybrid Water Heater Use & Care Manual (earlier revision), AP23657 Rev 01, page 34

Also listed in: Electric Residential Hybrid Water Heater Use & Care Manual (earlier edition), AP21681, page 29

What Rheem says to do

These steps involve electrical testing or parts replacement. Rheem's manuals tell owners to leave that work to a qualified service technician.

Replace Control Board

Last checked 2026-10-03.

Safety first

From the manufacturer's manual for this series.

The same code on other models

Codes mean different things on different heaters. Match the series to the model number on your rating label.

Other ProTerra / Performance Platinum hybrid (Gen V, 240V) codes