Hybrid Heater Codes

Rheem heat pump water heater

Rheem ProTerra 120V plug-in error codes

Covers: ProTerra 120V Plug-in Heat Pump Water Heater (Dedicated Circuit; and Shared Circuit with HydroBoost)

Every code listed in Rheem's own manual for this series, with what it means and what Rheem says to do. Last checked 2026-10-03.

Is this your model? For the 120V plug-in models: dedicated circuit (e.g. PROPH50 T0 RH120) and shared circuit with HydroBoost (e.g. PROPH65 T0 RH120-MSO, XE50T10HM00U0), as linked from Rheem's product pages. Same text display and buttons as the 240V Gen V models.

CodeLabelWhat the manual says it means
A004Comp.Shutdown: Discharge-Suction TripHeating source defaults to elements due to compressor malfunction
A005Compressor Shutdown: Discharge Temp HighHeating source defaults to elements due to compressor malfunction
T005Compressor Shutdown: Discharge Temp HighHeating source defaults to elements due to low airflow
A006Suction Temperature Too LowHeating source defaults to elements due to compressor malfunction
T006Suction Temperature Too LowHeating source defaults to elements due to compressor malfunction
T009Compressor wiring may be faultyHeating source default to elements due to compressor malfunction
A009Compressor wiring may be faultyHeating source default to elements due to compressor malfunction
A101Suction Temperature Sensor FailureHeating source defaults to elements due to heat pump temperature sensor malfunction
A102Ambient Temperature Sensor FailureHeating source defaults to elements due to heat pump temperature sensor malfunction
A103Lower Heater Temp Sensor FailureLower tank temperature sensor malfunction. Heater disabled.
A104Upper Heater Temp Sensor FailureLower tank temperature sensor malfunction. Heater disabled.
A105Evaporator Temp Sensor FailureHeating source defaults to elements due to heat pump temperature malfunction.
A106Discharge Temp Sensor FailureHeating source defaults to elements due to heat pump temperature malfunction.
A107Water Detected on Floor: Check For LeaksWater is detected in the drain pan
A108Condensate Blocked: Unclog LineHeating source defaults to elements due to condensate drain blockage
A130Unit Off/Air Temp Freezing: Enable UnitAmbient temperature is below freezing. --FREEZE WARNING
T131Clean Filter ReminderAir filter routine maintenance reminder
T132Water Heater difficulty satisfying demandWater heater can not satisfy demand
A120Shutoff Valve Can't Close ErrorShut-Off Valve malfunction
A121Shutoff Valve Can't Open ErrorShut-Off Valve malfunction
A122Shutoff Valve Inputs in ErrorShut-Off Valve malfunction
A123Shut-Off Valve Not InstalledShut-Off Valve malfunction
A200High Water Temp! [ECO] Call Tech ServiceECO Tripped. Heater Disabled
T300Water vor Not Installed [sic; as printed]Water Leak Sensor Not Installed
A502Time Clock needs to be programmedController malfunction. Heater disabled.
A503Time Clock not advancing time properlyController malfunction. Heater disabled.
T504WiFi Chip Communication ErrorController malfunction. Heater disabled.
A900Controller Fault: Call Tech ServiceController malfunction. Heater disabled.
T901Controller Fault: Call Tech ServiceController malfunction. Heater disabled.
A902Controller Fault: Call Tech ServiceController malfunction. Heater disabled.
A903Controller Fault: Call Tech ServiceController malfunction. Heater disabled.
A904Controller Fault: Call Tech ServiceController malfunction. Heater disabled.
A905Controller Fault: Call Tech ServiceController malfunction. Heater disabled.
A906Power Board Temp. Protection Sensor FailureController getting too hot.

Rheem's manual for this series does not list error codes; see the troubleshooting section below.