Hybrid Heater Codes

Bradford White · Heat pump RE2H (-1NCWT models)

Bradford White Heat pump RE2H (-1NCWT models) error code F20

What it means

Condensate drain pan port blocked. Water heater will only operate in Electric (Only) mode until the drain port is cleared and the sensor is no longer in contact with water.

The manual says the control must detect this 10 time(s) before the code is displayed.

Source: Bradford White Heat Pump Water Heater RE2H50, RE2H65, RE2H80 mini manual / quick reference (service), 238-52395-00 (file rev A), page 3

What Bradford White says to do

These steps involve electrical testing or parts replacement. Bradford White's manuals tell owners to leave that work to a qualified service technician.

Check main drain on condensate drain pan. Unblock if necessary. Check that the sensor is in the correct position in the drain pan, on the screw post near the main drain port. Ensure drain fittings do not reduce diameter at the drain pan port and cause water to build up in pan.

Last checked 2026-10-03.

Safety first

From the manufacturer's manual for this series.

The same code on other models

Codes mean different things on different heaters. Match the series to the model number on your rating label.

Other Heat pump RE2H (-1NCWT models) codes