Hybrid Heater Codes

Bradford White · Heat pump RE2H (-1NCWT models)

Bradford White Heat pump RE2H (-1NCWT models) error code F9

What it means

Lower heating element failure. Control energizes lower element, but current sensor detects no current flow.

The manual says the control must detect this 10 time(s) before the code is displayed.

Source: Bradford White Heat Pump Water Heater RE2H50, RE2H65, RE2H80 mini manual / quick reference (service), 238-52395-00 (file rev A), page 3

What Bradford White says to do

These steps involve electrical testing or parts replacement. Bradford White's manuals tell owners to leave that work to a qualified service technician.

Check respective heating element and wiring connections at element and control. Use service mode to cycle element and check current draw. Control assembly may have failed.

Last checked 2026-10-03.

Safety first

From the manufacturer's manual for this series.

The same code on other models

Codes mean different things on different heaters. Match the series to the model number on your rating label.

Other Heat pump RE2H (-1NCWT models) codes