Bradford White Heat pump RE2H (-1NCWT models) error code Fd

What it means

Control checks to ensure evaporator superheat is OK (controlled by EEV). Continuously verifies the temperature difference between T3a sensor (evap inlet temp) and T3b sensor (evap outlet temp) is greater than 5F after 30 mins of run time. Control also verifies that T3a is greater than 10F less than T5 ambient sensor.

The manual says the control must detect this 10 time(s) before the code is displayed.

Source: Bradford White Heat Pump Water Heater RE2H50, RE2H65, RE2H80 mini manual / quick reference (service), 238-52395-00 (file rev A), page 3

What Bradford White says to do

These steps involve electrical testing or parts replacement. Bradford White's manuals tell owners to leave that work to a qualified service technician.

Possible refrigerant leak. Check sealed system for leak. Check that filter is clean. Check T3a, T3b and T5 sensor mounting, wiring and resistance. Check EEV wiring at control, coil placement, and operation.

Last checked 2026-10-03.