Bradford White Heat pump RE2H (-1NCWT models) error code FJ

What it means

Control checks to ensure that the AC current draw is <= 20.5A while the compressor and lower heating element are both enabled. If current draw is >20.5A, the compressor will be disabled.

The manual says the control must detect this 10 time(s) before the code is displayed.

Source: Bradford White Heat Pump Water Heater RE2H50, RE2H65, RE2H80 mini manual / quick reference (service), 238-52395-00 (file rev A), page 3

What Bradford White says to do

These steps involve electrical testing or parts replacement. Bradford White's manuals tell owners to leave that work to a qualified service technician.

Check lower heating element rated wattage. Element wattage is stamped on the heating element terminal block. Correct wattage can be found on the water heater's rating plate.

Last checked 2026-10-03.

Safety first

From the manufacturer's manual for this series.

The same code on other models

Codes mean different things on different heaters. Match the series to the model number on your rating label.