Bradford White · Heat pump RE2H (-1NCWT models)
Bradford White Heat pump RE2H (-1NCWT models) error code FE
What it means
Control checks to ensure the compressor discharge temperature never exceeds 240F. Continuously verifies that T4 sensor (compressor outlet temperature) is less than 240F every minute of run time.
The manual says the control must detect this 10 time(s) before the code is displayed.
What Bradford White says to do
These steps involve electrical testing or parts replacement. Bradford White's manuals tell owners to leave that work to a qualified service technician.
Possible refrigerant leak. Check sealed system for leak. Check T4 sensor mounting, wiring and resistance. Check EEV wiring at control, coil placement, and operation.
Last checked 2026-10-03.
Safety first
- DISCONNECT POWER BEFORE SERVICING. IMPORTANT: RECONNECT ALL GROUNDING DEVICES. All parts capable of conducting electrical current are grounded; grounding wires, screws, straps, clips, nuts or washers removed for service must be returned to their original condition and properly fastened. (p.1)